Data Translation Inc.
Passionate About Measurement

24-Bit Isolated Ethernet DAQ Solutions

Data Translation ISO-Channel™ technology combines 24-bit ADC per channel with ±500V isolation between all inputs and to earth ground for ultra-accurate simultaneous DAQ.

ModelAnalog InputsResolutionInput RangeSample RateDigital I/OIsolationStarting Price*
DT8824 4DI 24-bit ±0.3125V, ±0.625V, ±1.25V, ±10V 4800Hz/ch 4 ±500V ch-ch $1895
DT8824-HV 4DI 24-bit ±18.75V, ±37.5V, ±75V, ±600V 4800Hz/ch 4 ±1000V ch-ch $2195
DT8837 4DI 24-bit ±1V,±10V 52.7kHz/ch 4 ±500V ch-ch $2995
DT8874 8DI-48DI 24-bit ±75mV, ±1.25V, ±10V, ±100V, ±400V 10Hz/ch 16 ±500V ch-ch $3695
DT8875 8DI-40DI 24-bit ±75mV, ±1.25V, ±10V, ±100V, ±400V 10Hz/ch 16 ±1400V ch-ch $9000
DT8876 4DI-20DI 24-bit ±75mV, ±1.25V, ±10V, ±100V, ±400V 10Hz/ch 16 ±3500V ch-ch $9000
VIBpoint-DT8837 16DI 24-bit ±1V,±10V 52.7kHz/ch 16 ±500V ch-ch $12695

*Price valid in US/Canada. Outside US/Canada, click here.

DT8824 and DT8824-HV
Isolated Precision DAQ
  • ±500V or ±1000V Isolation Ch-to-Ch and to earth ground
  • 4 simultaneous analog inputs
  • 24-bit Delta-Sigma ADC per channel
  • Input ranges of ±10V and ±600V
  • Up to 4800S/s/ch sampling
  • 4 opto-isolated digital output lines
  • CMRR of greater than 150dB
  • Included software and drivers
DT8824
DT8874
Ethernet Thermocouple, RTD, Voltage Measurement
  • ±500V Isolation Ch-to-Ch and to earth ground
  • 24-bit Delta-Sigma ADC per channel
  • Measure thermocouples, RTDs, or voltage
  • 8DI to 48DI channels
  • Up to 10S/s/ch sampling
  • 2U, ½ rack rugged enclosure
  • Included software and drivers
MEASURpoint
DT8876
Ethernet Thermocouple, RTD, Voltage Measurement
  • ±3500V Isolation Ch-to-Ch and to earth ground
  • 24-bit Delta-Sigma ADC per channel
  • Measure thermocouples, RTDs, or voltage
  • 4DI to 20DI channels
  • Up to 10S/s sampling per channel
  • 5U, 19-inch rack or surface mountable rugged enclosure
  • Included software and drivers
MEASURpoint
DT8837
Ethernet Sound and Vibration DAQ
  • ±500V Isolation Ch-to-Ch and to earth ground
  • 24-bit Delta-Sigma ADC/ch 
  • Up to 52.7 kS/s/ch sampling
  • Analog out, tach, C/Ts synchronized w/analog in
  • Multiple module synchronization using Wired Trigger Bus
  • 1U, ½ rack rugged enclosure
  • Includes trial version of VIBpoint Framework
DT8837
DT8875
Ethernet Thermocouple, RTD, Voltage Measurement
  • ±1400V Isolation Ch-to-Ch and to earth ground
  • 24-bit Delta-Sigma ADC per channel
  • Measure thermocouples, RTDs, or voltage
  • 8DI to 40DI channels
  • Up to 10S/s/ch
  • 5U, 19-inch rack or surface mountable rugged enclosure
  • Included software and drivers
MEASURpoint
VIBpoint-DT8837
Sound and Vibration DAQ Solutions
  • DT8837 hardware bundled with VIBpoint Framework application
  • Supports 16 IEPE or voltage inputs and a tachometer that can be triggered simultaneously
VIBpoint Instruments